FRONT PAGE |
EQUIP INDEX |
| Metric to AWG | ||
| mm2 | Diam. mm | AWG |
| 0.5 | 0.8 | 20 |
| 0.8 | 1.0 | 18 |
| 1.0 | 1.3 | 16 |
| 2.0 | 1.6 | 14 |
| 3.0 | 2.1 | 12 |
| 5.0 | 2.6 | 10 |
| 8.0 | 3.3 | 8 |
| 13.0 | 4.8 | 6 |
| 19.0 | 5.2 | 4 |
| 32.0 | 6.5 | 2 |
| 52.0 | 8.3 | 0 |
Note: These tables have been converted from Imperial dimensions and are approximate.
| Wire Gauge Selection Table - 12 volts | |||||||
| Amps | Wire Gauge for circuit length in metres | ||||||
| 1m | 1.5m | 2m | 3m | 5m | 6m | 8m | |
| 0 to 5 | 18 | 18 | 18 | 18 | 18 | 18 | 18 |
| 6 | 18 | 18 | 18 | 18 | 18 | 18 | 16 |
| 7 | 18 | 18 | 18 | 18 | 18 | 18 | 16 |
| 8 | 18 | 18 | 18 | 18 | 18 | 16 | 16 |
| 10 | 18 | 18 | 18 | 18 | 16 | 16 | 16 |
| 11 | 18 | 18 | 18 | 18 | 16 | 16 | 14 |
| 12 | 18 | 18 | 18 | 18 | 16 | 16 | 14 |
| 15 | 18 | 18 | 18 | 18 | 14 | 14 | 12 |
| 18 | 18 | 18 | 16 | 16 | 14 | 14 | 12 |
| 20 | 18 | 18 | 16 | 16 | 14 | 12 | 10 |
| 22 | 18 | 18 | 16 | 16 | 12 | 12 | 10 |
| 24 | 18 | 18 | 16 | 16 | 12 | 12 | 10 |
| 30 | 18 | 16 | 16 | 14 | 10 | 10 | 10 |
| 40 | 18 | 16 | 14 | 12 | 10 | 10 | 8 |
| 50 | 16 | 14 | 12 | 12 | 10 | 10 | 8 |
| 100 | 12 | 12 | 10 | 10 | 6 | 6 | 4 |
| 150 | 10 | 10 | 8 | 8 | 4 | 4 | 2 |
| 200 | 10 | 8 | 8 | 6 | 4 | 4 | 2 |
18AWG not recommended for mobile use.